Hotpoint GF641TX Instrucciones de uso Pagina 7

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 12
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 6
GB
7
PLEASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24
RR
TC
S
A
GF640TX
GF641TX
Table 1 Liquid Gas Natural Gas
Burner Diameter Thermal Thermal By-pass Nozzle Flow* Nozzle Flow*
power power 1/100 1/100 (g/h) 1/100 (l/h)
kW kW
(p.c.s.*) (p.c.s.*)
(mm) Reduced Nominal (mm) (mm) *** ** (mm)
Supply pressures Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
28-30
20
35
37
25
45
20
17
25
Reduced Fast (RR)
Semi Fast (S)
Auxiliary (A)
Triple Crown (TC)
100
75
55
130
0.70
0.40
0.40
1.50
2.60
1.65
1.00
3.25
39
28
28
61
80
64
50
91
189
120
73
236
186
118
71
232
110(Y)
96(Z)
71
133
248
157
95
309
Burner and nozzle specifications
* At 15°C and 1013,25 mbar - dry gas
** Propane P. C.S. = 50.37 MJ/Kg
*** Butane P. C.S. = 49.47 MJ/Kg
Natural P. C.S. = 37.78 MJ/m³
8,50 (618 g/h - G30) (607 g/h - G31)
GF640TX
GF641TX
II2H3+
Gas section
Rated power (kW)Class
Model
Electric section
220-240V~ 50/60Hz
Voltage and frequency
(1)
Power (W)
0,6
The values in g/h refer to the capacities with liquid gas (Butane, Propane).
(1)
Vista de pagina 6